130
Tabela 6.1 - Pressão máxima admissível de vento (kN/m
2
) em painéis de LSF, com
flecha máxima de L/240
2400 2700 3000 3600 4200
Ue 100x50x12x1,2 3,183 2,235 1,629 0,943 0,594
Ue 100x50x12x1,5 3,950 2,777 2,022 1,170 0,737
Ue 100x50x12x2,0 5,000 3,636 2,651 1,534 0,966
Ue 150x50x12x1,2 5,000 5,000 4,171 2,414 1,520
Ue 150x50x12x1,5 5,000 5,000 5,000 3,004 1,890
Ue 150x50x12x2,0 5,000 5,000 5,000 3,955 2,491
Ue 200x63x14x1,2 5,000 5,000 5,000 5,000 3,550
Ue 200x63x14x1,5 5,000 5,000 5,000 5,000 4,415
Ue 200x63x14x2,0 5,000 5,000 5,000 5,000 5,000
FLECHA MÁXIMA L/240
Seção Montante
Altura do vão (L) vencido pelo fechamento (mm)
Fonte: HADLEY GROUP, 2005, p.17
Tabela 6.2 - Pressão máxima admissível de vento (kN/m
2
) em painéis de LSF, com
flecha máxima de L/360
2400 2700 3000 3600 4200
Ue 100x50x12x1,2 2,122 1,490 1,086 0,629 0,396
Ue 100x50x12x1,5 2,633 1,849 1,348 0,780 0,491
Ue 100x50x12x2,0 3,451 2,424 1,767 1,023 0,644
Ue 150x50x12x1,2 5,000 3,814 2,781 1,609 1,013
Ue 150x50x12x1,5 5,000 4,746 3,460 2,002 1,261
Ue 150x50x12x2,0 5,000 5,000 4,557 2,637 1,661
Ue 200x63x14x1,2 5,000 5,000 5,000 3,792 2,388
Ue 200x63x14x1,5 5,000 5,000 5,000 4,620 2,984
Ue 200x63x14x2,0 5,000 5,000 5,000 5,000 3,943
FLECHA MÁXIMA L/360
Seção utilizada
Altura do vão (L) vencido pelo fechamento (mm)
Fonte: HADLEY GROUP, 2005, p.17
Tabela 6.3 - Pressão máxima admissível de vento (kN/m
2
) em painéis de LSF, com
flecha máxima de L/600
2400 2700 3000 3600 4200
Ue 100x50x12x1,2 1,273 0,894 0,652 0,377 0,238
Ue 100x50x12x1,5 1,580 1,110 0,809 0,468 0,295
Ue 100x50x12x2,0 2,071 1,454 1,060 0,614 0,386
Ue 150x50x12x1,2 3,258 2,289 1,668 0,965 0,608
Ue 150x50x12x1,5 4,055 2,848 2,076 1,201 0,757
Ue 150x50x12x2,0 5,000 3,750 2,734 1,582 0,996
Ue 200x63x14x1,2 5,000 5,000 3,932 2,275 1,433
Ue 200x63x14x1,5 5,000 5,000 4,783 2,852 1,770
Ue 200x63x14x2,0 5,000 5,000 5,000 3,757 2,366
FLECHA MÁXIMA L/600
Seção utilizada
Altura do vão (L) vencido pelo fechamento (mm)
Fonte: HADLEY GROUP, 2005, p.17